Hot Sale Biomass electric generator/CNG gas generator/Silent gas generator/Gas cogenerator/Gas energy generator 20KW-200KW


Advantages for gas engine

1. Adopt Cummins engine block, so the instructure is very strong. Also it is easy for customer to get maintenance spare parts.

2. Adopt advanced Hall ignition sensor and Highly capable USA Altronic ignition system, the engine ignition will be more reliable and easier to start. Besides, there is Top End Center mark on the engine, it is easy for users to adjust the top end certer when commissioning generator set.

3. Adopt ComAp Interligen/Interlisys controller to make synchronization for generator set, all the parameters can be set in the program and can realize the remote controlling through cell phone or computer.

4. The gas inlet pressure is only 2~12kPA, so almost all city pipe gas pressure can be satisfied, not to mention biogas. So there is no need for customer to install blower to increase pressure and save cost for you.

5. Electrical Air/Gas mixer. The mixer guarantees optimum air-fuel ratio to improve efficiency and reduce NOx emission. Unique air-fuel ratio adjusting system is suitable for 30%~90% methane concentration.

6. Long designed overhaul term: 25000~30000 hours

7. Comply with CE standard, ISO9001: 2008 quality management system, ISO14001: 2004 and OHSAS 18001: 2007.


Standard working conditions

1. Genset can run for continuously at rated power on the conditions of:

Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.

2. Genset can also run stably and reliably on the conditions of:

Ambient Temp-40° C~+40° C, Relative Humidity<90%(20° C), Altitude≤ 1000mabove sea level.

Fuel requirements if fuel is biogas

1. Adapted Gas: Biogas(Marsh gas)

2. AcceptableBiogaspipeline pressure: 2~12kPa

3. Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat valueincrease, if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it willl lower the power efficiency.

4. CH4 content≥ 50%.

5. Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )

6. Sulphur content≤ 200mg/Nm3, the excessive sulphur in impurity gas should be removed.

(CAMDA H Series Biomass Generator Set Specifications)

   Model 

Item    
 

KDGH30-G
 

KDGH50-G
 

KDGH80-G
 

KDGH120-G
 
 

Power (KVA/kWe)
 

37/30
 

62/50
 

100/80
 

150/120
 
 

Rated Voltage (V)
 

400/230
 

400/230
 

400/230
 

400/230
 
 

Frequency (Hz)
 

50
 

50
 

50
 

50

 

Speed (RPM)
 

1500
 

1500
 

1500
 

1500

 

Engine model
 

HG4B
 

HG6B
 

HGN14
 

HGN14
 


 

Mechanical

Efficiency (%)
 

36.5
 

37.4
 

37.8
 

38.5
 


 

Electrical

Efficiency (%)
 

34.6
 

35.5
 

35.7
 

36.4
 

 

Rated current ( A )
 

45
 

90
 

135
 

217
 
 

Voltage   Stabilized regulation
 

≤±1.5%
 

≤±1.5%
 

≤±1.5%
 

≤±1.5%
 

 

Voltage Instantaneous regulation
 

≤±20%
 

≤±20%
 

≤±20%
 

≤±20%
 

 

Voltage Recovery time ( S )
 

≤1
 

≤1
 

≤1
 

≤1
 
 

Voltage Fluctuation ratio
 

≤1%
 

≤1%
 

≤1%
 

≤1%
 

 

Voltage Wave aberration ratio
 

≤5%
 

≤5%
 

≤5%
 

≤5%
 

 

Frequency     Stabilized regulation
 

≤1%(adjustable)
 

≤1%(adjustable)
 

≤1%(adjustable)
 

≤1%(adjustable)
 
 

Frequency Instantaneous regulation
 

-10% ~ 12%
 

-10% ~ 12%
 

-10% ~ 12%
 

-10% ~ 12%
 

 

Frequency   Recovery time ( S )
 

≤7
 

≤7
 

≤7
 

≤7
 
 

Frequency Fluctuation ratio
 

≤1%
 

≤1%
 

≤1%
 

≤1%

 

Generator Insulation class
 

H
 

H
 

H
 

H
 

 

Noise level ( dB )
 

≤95
 

≤95
 

≤95
 

≤95

 

Dry weight ( kg )
 

900
 

1100
 

1700
 

2600
 


 

Dimension(mm)
 

1800x710x1350
 

2250x820x1400
 

2450x820x1550
 

2800x1100x1550
 

 

Prod Model: HG4B, HG6B, HGN14, HGK19
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Speed: 1500rpm/1800rpm
Frequency: 50Hz/60Hz
Rated Power: 20kw to 200kw
Rated Voltage: 230V, 400V, 220V, 415V, 380volt, etc.
Rated Current: 60A to 360A
Fuel Type: Biomass, Natural Gas(CNG)/LPG/Wood Gas
Auto Controller: Auto and Intelligent UK Deep Sea 6020 or Comap Ig-
Acceptable Gas: Biogas, Natural Gas, LPG, CNG, Coalmine Gas
Efficiency: High
Gas Source: Gas
Output Type: AC Three Phase
Camda New Energy Equipment Co., Ltd Established in 1998, Camda began to engage in manufacturing and servicing DIESEL GENERATOR, supplying a wide range of products, such as Cummins, Perkins, Lovol, Daewoo, Deutz, etc. With production reaching 5000 pieces annually, Camda diesel generator includes:

Cummins: Prime power 18kw (22.5kVA) - 1080kw(1350kVA)

Perkins: Prime power 8kw (10kVA) - 1800kw ( 2250kVA)

Daewoo: Prime power 130kw (162kVA) - 600kw (750kVA)

Deutz: Prime power 20kw (25kVA) - 120kw (150kVA)

For GAS GENERATOR, presently Camda can supply natural gas and biogas generator from GE Jenbacher, Wachesha, Daewoo. We are the most important distributor of GE Jenbacher and Wachesha in China. Our own brand gas generator, Camda H series, is developed by us in cooperation with Cummins and has been displayed at Shanghai Expo 2010. Camda gas genset is in service in UK, Russia, Italy, and many other countries, with power ratings:

Camda H series: 24kw (30kVA) - 500kw (625kw)

Daewoo: 100kw (125kVA) - 310 (387.5kVA)

Camda also is an experienced package system supplier engaged in biogas production and power generation. We can take projects from conception to implementation, including design, project management, manufacturing, installation and commissioning. Camda's biogas power plant covers landfill, farm waste, and food waste.

Accomplished around 170 biogas power plants in China.

Investing and operating 2 landfill site (CDM project), fitted up with gas generator with power output of 10 MW.

Built up a demo project processing 10 tons/day of food waste.

Send your message to this manufacturer

  • Camda New Energy Equipment Co., Ltd.

More >

Other Generator Products with This Manufacturers

About Us Generator Products Generator Manufacturers Hot Generator Generator News Generator Trade Shows Site Partners Contact Us Sitemap