Control the burner ignition and flame monitoring;
Lock alarm after extinguish;
Work Life: 1X106 Times.
Can control the gas burner ignition under any power;
Can be used ionization flame monitoring or ultraviolet UV monitoring;
Ignition and monitoring can be completed by one electrode;
There is lock alarm after extinguish;
The terminals of the live wire and the zero line can not be interchangeable;
Two groups terminals with normal and fault output;
Tested and approved by EC Directive90/396/EEC and in line with standards of European Gas Application EN298;
Current under flame monitoring can be adjusted between 2-20 microamp;
High voltage ignition cable is better less than 1 meter;
Reset only after alarm lights;
Output Current: The maximum current for every output is 2A; Maximum total current is 2.5A;
Fuse: 2A, Slow Melt H-Line with IEC127-2/5;
Work Life: 1X106 Times, 270000 Times for Single-electrode;
Ambient Temperature: Minus 10 celsius degree to 60 celsius degree; Any condensation is not allowed;
Protection Level: IP40 meets IEC529.
Foshan Denk Energy Technique Co., Ltd.Is the most professional combustion equipment research and development and the manufacturer of the world.We committed top brand to offer combustion equipment R&D and manufacturing services.And provides design, debugging and installation for the industrial furnace and combustion control system according to the customer's requirement.