1200kw/1500kva Cummins engine Diesel power Generator
1) Cummins engine, Standford/Marathon/Leroy somer generator
2) Prime Power: 1200 kw, Voltage: 230/400V,
4) Certificate: ISO90001/ ISO14001/CE/
5) 12 months warranty
We have got through the international quality certification system of ISO9001-2000, International environmental protection certification of ISO 14001: 2004, China Compulsory Certification and CE certification.
1. Technical parameters of Engine:
Producer: Cummins Power: 1200kw Engine Model: KTA50 Displacement of piston: 50 Power factor: 0.8Governor way: Mechanical Insulation: HProtection: IP23Fuel: 0 light diesel
Intake way: Normally AspiratedRated output Voltage: 380/440V(optional)Rated Frequency(Hz): 50/60(optional)Rated speed: 1500r/mVoltage Control: AVRSoundproof Canopy(the color of the canopy can be changed)Norminal ambient condition of genset: Sea level elevation of 1500m, ambient temperature of 40 Celsius degree.
2. Technical parameters of Alternator:
Brand: Stamford/Marathon/Leroy Somer(Optional)Frequency fluctuation: ≤ ± 0.5%Frequency regulation: ≤ ± 0.5%(stable)Voltage Setting Range: ≥ ± 5%Temperature Rise: HClass of Insulation: HGrade of Protection: IP22Efficiency: 93.60%Electromagnetism Interference Factor: THF<2%, TIF<50Steady Voltage Regulation Factor: ≤ ± 1.0%
3. Technical parameters of Control Panel:
Brand: Smartgen/Upwin/Deepsea(Optional)Start or stop generator set Manually/AutomaticallyGenerator over/under frequency protectionOpen controller output can be defined as Pre-heat/Idle outputGenerator over/under/unbalance voltage protectionHigh coolant temperature protectionOver speed protectionLow oil pressure protectionOver current protectionOver load protectionAvailable for remote controlNote: Indicate this function depeed on the set points of the controller in field.
INSPECTION AND TEST
1 GENERAL
1.1 Each engine shall be tested at manufacturers workshop to certify the engine output and fuel consumption in accordance with the site operating condition specified by purchaser on the specification datasheet.
1.2 All relevant information drawings pertinent to the testing and test procedure shall be transmitted to the purchaser in advance of the test date notification.
1.3 The engine and generator shall be tested separately in accordance with relevant standards specified above.
1.4 The completed and individually tested engine and generator shall be assembled onto the baseplate with all auxiliaries, instruments and controls for a complete test of the generator set.
Product line
1. Open type gensets.
2. Silent type gensets.
3. Trailer mounted gensets.
4. Enviromental protection and noise reduction project.
Item | KVA | KW | Engine Model | Alternator |
Prime | Standby | Prime | Standby | ENGGA | Stamford |
HNC25 | 23 | 25 | 18 | 20 | 4B3.9-G2 | ENGGA | PI 144E |
HNC30 | 28 | 30 | 22 | 24 | 4B3.9-G2 | ENGGA | PI 144F |
HNC45 | 40 | 45 | 32 | 36 | 4BT3.9-G2 | ENGGA | PI 144J |
HNC56 | 50 | 56 | 40 | 45 | 4BTA3.9-G2 | ENGGA | UCI 224D |
HNC63 | 56 | 63 | 45 | 50 | 4BTA3.9-G2 | ENGGA | UCI 224E |
HNC100 | 90 | 100 | 72 | 80 | 6BT5.9-G2 | ENGGA | UCI 224G |
HNC115 | 103 | 115 | 82 | 92 | 6BT5.9-G2 | ENGGA | UCI 274C |
HNC138 | 125 | 138 | 100 | 110 | 6BTA5.9-G2 | ENGGA | UCI 274D |
HNC150 | 138 | 150 | 110 | 120 | 6BTAA5.9-G2 | ENGGA | UCI 274E |
HNC178 | 160 | 178 | 128 | 142 | 6CTA8.3-G2 | ENGGA | UCI 274F |
HNC200 | 183 | 200 | 146 | 160 | 6CTA8.3-G2 | ENGGA | UCI 274G |
HNC225 | 200 | 225 | 160 | 180 | 6CTAA8.3-G2 | ENGGA | UCI 274H |
HNC250 | 225 | 250 | 180 | 200 | 6LTAA8.9-G2 | ENGGA | UCDI 274J |
HNC275 | 250 | 275 | 200 | 220 | 6LTAA8.9-G2 | ENGGA | UCDI 274K |
HNC275 | 250 | 275 | 200 | 220 | MTA11-G2A | ENGGA | UCDI 274K |
HNC350 | 313 | 350 | 250 | 280 | MTAA11-G3 | ENGGA | HCI 444ES |
HNC275 | 250 | 275 | 200 | 220 | NT855-GA | ENGGA | UCDI 274K |
HNC313 | 275 | 313 | 220 | 250 | NTA855-G1A | ENGGA | HCI 444D |
HNC350 | 313 | 350 | 250 | 280 | NTA855-G1B | ENGGA | HCI 444ES |
HNC375 | 344 | 375 | 275 | 300 | NTA855-G2A | ENGGA0 | HCI 444E |
HNC400 | 350 | 400 | 280 | 310 | NTA855-G4 | ENGGA | HCI 444E |
HNC450 | 400 | 450 | 320 | 360 | NTAA855-G7A | ENGGA | HCI 444F |
HNC413 | 375 | 413 | 300 | 330 | KTA19-G2 | ENGGA | HCI 444FS |
HNC500 | 450 | 500 | 360 | 400 | KTA19-G3 | ENGGA | HCI 544C |
HNC563 | 500 | 563 | 400 | 450 | KTA19-G4 | ENGGA | HCI 544D |
HNC630 | 563 | 630 | 450 | 500 | KTAA19-G5 | ENGGA | HCI 544D |
HNC650 | 575 | 650 | 460 | 520 | KTA19-G8 | ENGGA | HCI 544E |
HNC688 | 625 | 688 | 500 | 550 | KTAA19-G6A | ENGGA | HCI 544FS |
HNC713 | 650 | 713 | 520 | 570 | QSKTAA19-G3 | ENGGA | HCI 544F |
HNC825 | 750 | 825 | 600 | 660 | KTA38-G2 | ENGGA | HCI 634G |
HNC888 | 800 | 888 | 640 | 710 | KTA38-G2B | ENGGA | HCI 634G |
HNC1000 | 913 | 1000 | 730 | 800 | KTA38-G2A | ENGGA | HCI 634H |
HNC1100 | 1000 | 1100 | 800 | 880 | KTA38-G5 | ENGGA | HCI 634J |
HNC1250 | 1125 | 1250 | 900 | 1000 | KTA38-G9 | ENGGA | HCI 634K |
HNC1375 | 1250 | 1375 | 1000 | 1100 | QSK38-G5 | ENGGA | LVI 634G |
HNC1400 | 1250 | 1400 | 1000 | 1120 | KTA50-G3 | ENGGA | LVI 634G |
HNC1625 | 1500 | 1625 | 1200 | 1300 | KTA50-G8 | ENGGA | PI 734C |
HNC1675 | 1500 | 1675 | 1200 | 1340 | KTA50-GS8 | ENGGA | PI 734C |
Guangdong Hainengquanyu Power-Tech Co., Ltd was incorporated in Dongguan City on Jan 8th, 1999, which is located in the world production base at the most economically developed Pearl River Delta of China.
Haineng is one of the largest supplier of both imported and local diesel generator set in Southeast Asia and southern part of China. Based on the operating management with scientific thining and humanity, many top talents with high profile, high technology and high qualifications at home and abroad gathered here. There are more than xis hundred staff in total, including seven senior engineers. Sixty-nine domestic senior engineers, one hundred and thirty-eight intermediate engineers. There are both domestic and foreign engine brands like Cummins, Volvo, Doosan Dewoo, Shanghai, Yuchai, Jichai, Weichai and so on.
We have a a powerful sales team and a comprehensive distribution network which is based on Guangdong province and extended to the whole nation. In addition to setting up offices in cities and twons in Guangdong province, we also hvae built many offices and branches in different tech enterprises composed of production, scientific research, design, project reforem and envrionmental noise reduction, new energy resources.
We have a reasonable product mix with capacity covered 5kVA -3000kVA. We provide a full range of gensets in addition to general -purpose ones, whicn include the marine sets, plateau sets, high pressure sets and sets with frequency of 50Hz-60 Hz. WE ALSO PROVIDE CONTROL EQUIPMENT OF SELF-STARTING, self switching, three -phase monitoring, automatic parallel operation and special genset like silent type, trailer type, container type, hook type of refrigeated trunks and other special type of split cooling units for users to choose. Meanwhile, we offer other ancillary work and service like project of environmental noise reduction, repairent and maintenance for the gensets. In order to ensure the quality of prodcts, we built a high precison testing equipment monitoring by computer completely to testing each generator accurately before leaving the factory.